FITTING GUIDE

SCR UNIT FITTING GUIDE

PART NO. BM31073H SCR unit · hot end emissions
⚠
IMPORTANT SAFETY NOTE
All work must be carried out by a qualified and experienced mechanic or trained vehicle technician. Allow the exhaust system to cool fully before starting any work.
01 REMOVAL PROCEDURE
1
Disconnect all lambda sensor connectors, differential pressure sensor connectors, and associated pressure pipes.
2
Disconnect any Urea injector connections where fitted.
3
Remove any heat shields or components restricting access.
4
Support the exhaust system before separating any joints.
5
Remove the front clamp connection from the upstream exhaust component.
6
Disconnect the rear clamp connection from the remaining exhaust system.
7
Carefully remove the SCR assembly from the vehicle.
8
Inspect all mounting points, sensors, and pipework for damage or contamination.
02 PRE-INSTALLATION UREA INJECTOR CHECK
Crystallised urea deposits may form within the injector or associated pipework, particularly where vehicles are used for repeated short journeys or where the system has not reached full operating temperature. Before installation, it is recommended to:
  • Inspect the AdBlue/DEF injector for signs of crystallisation or blockage.
  • Ensure the injector nozzle is clear and functioning correctly.
  • Check associated pipework for contamination or restriction.
Failure to address injector contamination may result in poor system performance, warning lights, or repeat faults after installation. Where contamination is present, further diagnosis of the SCR system should be carried out before fitting the replacement unit.
03 FITTING THE NEW SCR
1
Position the catalytic converter / DPF assembly into place.
2
Loosely connect the front clamp to the upstream exhaust component. Do not fully tighten at this stage.
3
Loosely connect the rear clamp to the remaining exhaust system.
4
Align the assembly before final tightening.
5
Tighten the front clamp connection first, then the rear clamp evenly.
6
Reconnect all sensors, differential pressure pipes, and AdBlue/DEF injector connections.
7
Refit all heat shields and removed components.
04 FINISHING NOTES
⊘ Do not use exhaust paste on joints ahead of the SCR.
✓ After installation, run the engine to operating temperature and check for exhaust leaks and correct exhaust alignment.

© 2026 BM Catalysts Limited. All rights reserved.

VAT number: 290 8703 83

Company registration number: 1673421

​